Inspection IDReason for InspectionInspection DateInspection Status 
SIN-00230780 Renewal 08/15/2023 Compliant - Finalized
RegulationLIS Non-Compliance AreaCorrection RequiredPlans of CorrectionCorrection DatePOC Status
6400.63(a)On 8/16/23, the hot water temperature at the bathroom sink in the ensuite bathroom connected to bedroom #1 measured 152.7 degrees Fahrenheit at 11:29 AM. The hot water temperature at the kitchen sink measured 153.3 degrees Fahrenheit at 11:38 AM.Heat sources, such as hot water pipes, fixed space heaters, hot water heaters, radiators, wood and coal-burning stoves and fireplaces, exceeding 120°F that are accessible to individuals, shall be equipped with protective guards or insulation to prevent individuals from coming in contact with the heat source. The water heater was adjusted prior to the protective guard being purchased. 09/20/2023 Implemented
6400.106The home was not able to provide documentation that the furnace was inspected and cleaned. The home has been operating since 11/11/2022.Furnaces shall be inspected and cleaned at least annually by a professional furnace cleaning company. Written documentation of the inspection and cleaning shall be kept. Not Forgotten scheduled all furnace at all sites be inspected and clean twice a year (April and October) be a licensed HVAC company-Admiral Heating and Cooling. 09/20/2023 Implemented