Inspection IDReason for InspectionInspection DateInspection Status 
SIN-00219194 Renewal 02/13/2023 Compliant - Finalized
RegulationLIS Non-Compliance AreaCorrection RequiredPlans of CorrectionCorrection DatePOC Status
6400.66The light outside the front exit door is inoperable. There is not another source of light in that area.Rooms, hallways, interior stairways, outside steps, outside doorways, porches, ramps and fire escapes shall be lighted to assure safety and to avoid accidents. The porch light was replaced and the circuit box was fixed, ensuring that outside lighting is operable. 03/01/2023 Implemented
6400.82(e)The bathtub in the bathroom on the first floor of the home did not have a nonslip surface or mat. Bathtubs and showers shall have a nonslip surface or mat. A non slip Matt was added to the bathtub. 02/28/2023 Implemented
6400.101There is a turn lock on the basement side of the door between the basement and the garage posing an obstructed egress from the garage when engaged. There is not a ''man door" inside the garage. There is a padlock on the door leading to the staff office in the basement of the home.Stairways, halls, doorways, passageways and exits from rooms and from the building shall be unobstructed. The padlock has been removed from the door leading to the staff office in the basement of the home. In addition, the turn lock on the basement side of the door between the basement and the garage has been removed. 03/03/2023 Implemented
6400.110(b)The closest smoke detector to Individual #1's bedroom is 16 feet away.There shall be an operable automatic smoke detector located within 15 feet of each individual and staff bedroom door. In operable smoke detector has been installed within 15 feet of the individual's bedroom. 02/16/2023 Implemented
6400.214(b)Individual #1's most recent physical examination was not at the home. The most current copies of record information required in § 6400.213(2)¿(14) shall be kept at the residential home. The individuals updated physical was placed at the home, to be included with the individual's entire file. 02/27/2023 Implemented
6400.46(d)Direct Service Worker #1's first aid and CPR training, completed on 5/29/2022, did not include an in-person component. Direct Service Worker #2's first aid and CPR training, completed 6/27/2022, did not include an in-person component.Program specialists, direct service workers and drivers of and aides in vehicles shall be trained within 6 months after the day of initial employment and annually thereafter, by an individual certified as a training by a hospital or other recognized health care organization, in first aid, Heimlich techniques and cardio-pulmonary resuscitation.The direct service worker #1 and #2 both have retaken the CPR and first aid course, with an in-person course. Documentation has been placed into the staff training file. 02/23/2023 Implemented
SIN-00202481 Renewal 03/02/2022 Compliant - Finalized
RegulationLIS Non-Compliance AreaCorrection RequiredPlans of CorrectionCorrection DatePOC Status
6400.112(e)A fire drill was held during sleeping hours on 6/14/21 at 10 PM. No other fire drill was held during sleeping hours, exceeding the 6 month requirement.A fire drill shall be held during sleeping hours at least every 6 months. The fire drill was completed on 12/13/21 at 10 pm but did not indicate that it was a sleeping drill. The agency has revised the fire drill log to reflect the agency's sleeping hours: 10:00 pm- 7:00 am. In addition, supervisors have been trained on the use and completion of the revised form. [copy of fire drill form indicating sleeping hours and that individuals must be sleeping received on 5/19/22 and reviewed on 5/20/22. Copies of fire drill training forms for staff, dated 3/12/22, received on 5/19/22 and reviewed on 5/20/22. DPOC by HDKP, HSLS, on 5/20/22]. 04/01/2022 Implemented
SIN-00238725 Renewal 02/06/2024 Compliant - Finalized
SIN-00185651 Renewal 03/31/2021 Compliant - Finalized